chinese    english
 
    This kind of Resistance-reduce-agent is composed of many ingredients, including electrolyte, curing agent, lubricant, electro-conductive cement and stuffing materials. As one excellent electric conductor, it is used between grounding part and earth. On the one hand, it can be closely connected to metal grounding to form enough current surface; on the other hand, it can infiltrate into soil near it to lower resistance and form one low resistance district around grounding parts.
 
 
     
 
Name: @
Pass:
 
 
10.Surge Protection Device for Low-pressure Direct Current Power

■ QPDC direct current power parallel type surge protection device

Type
QPDC-12
QPDC-24
QPDC-48
QPDC-110
QPDC-220
QPDC-300
  Order No.
5140
 
5141
5142
5143
5144
5145
  Rating Working Voltage Uo
12V
 
24V
48V
110V
220V
300V
 Nominal Flow of Every Route lo
20KA
 
20KA
20KA
20KA
20KA
20KA
 Continuous Anti-pressure of Every Route Uc
18V
38V
85V
180V
300V
700V
  Protection Level Up
196V
245V
310V
510V
650V
<1000V
  Touch Current lo
<10μA
  Max. Dimension for Connecting Terminal
≤ 16mm2 multiplied yarn or 25mm2 single wire
  Connecting Terminal Way
Parallel
  Installation Way
35mm Standard Mounting Rail
  Function Characteristic
aging guideline, aging thermal trip and short over-current trip (stopping fire and blast), hot backup
  Application Domain
for equipment of low-voltage direct current
  External Dimension
36mm×71mm×88mm
 

■QPAC Low-voltage direct cross power supply surge protection device

 Type QPAC-12   QPAC-24 QPAC-48 QPAC-110
  Order No.   5150   5151   5152   5153
  Rating Working Voltage Uo   12V   24V   48V   110V
  Rating Working Current lo   20KA   20KA   20KA   20KA
  Nominal Flow of Every Route lmax   88V   85V   180V   300V
  Static Threshold Voltage (1mA)   245V   310V   510V   650V
  Dynamic Residual Voltage (1KV/s)   <10μA
  Max. Connecting Terminal Dimension   ≤ 16mm2 multiplied yarn or 25mm2 single wire
  Connecting Terminal Way   Parallel
  Installation Way   35mm Standard Mounting Rail
  Function Characteristic   aging guideline, aging thermal trip and short over-current trip (stopping fire and blast), hot backup
  Application Domain   for equipment of low-voltage direct current
  External Dimension   36mm×71mm×88mm

■QPD Direct current power circuit series type surge protection device

 Type          QPD-12     QPD-24     QPD-48    
  Order No.  5200   5201   5202
  Rating Working Voltage Uo  12VDC   24VDC   48VDC
  Rating Working Current lo  10A   10A   10A
  Nominal Flow of Every Route lmax  10KA   10KA   10KA
  Static Threshold Voltage (1mA)  18DVC   36DVC   68DVC
  Dynamic Residual Voltage (1KV/s)  <30DVC  <60DVC  <100DVC
  Max. Connecting Terminal Dimension  ≤4mm2
  Connecting Terminal Way  Series, bolt fixing
  Installation Way  35mm Standard Mounting Rail
  Function Characteristic  three-grade protection; it will intermit if product aging; crust is anti-flame; hot backup
  Application Domain  communications, supervision and industrial automatization
  External Dimension  90mm×181mm×67mm